Air conditioner leaking water
An AC makes water every hour it runs. A leak means that water is not getting to the drain.
Get quotes Repair cost calculator
Written by HYRE HVAC Research Desk Primary-source research, data analysis and fact checking
The short answer
An air conditioner leaking water usually has a clogged condensate drain line, a full or cracked drain pan, a frozen evaporator coil that is thawing, a failed condensate pump, or a disconnected drain. Turn the system off to stop more water, protect the floor or ceiling, and check the filter.
Clearing a blocked drain at the cleanout is often within reach; a cracked pan, a pump failure or a recurring freeze needs a technician.
Do this now
This stops new condensate. If water is near electrical parts or outlets, switch off the breaker for the indoor unit too.
Towels, a bucket, and move belongings. For a ceiling stain under an attic unit, catch the drip and keep people away if the ceiling bulges.
Pull the filter. If you cannot see light through it, replace it. A clogged filter starves the system of airflow. ENERGY STAR suggests checking it monthly in heavy-use seasons.
Where the water comes from
| What you see | Likely cause | Who fixes it |
|---|---|---|
| Water around the furnace or air handler | Clogged condensate drain | Often you, at the cleanout; recurring: technician |
| Water after ice melts | Frozen coil from low airflow or low refrigerant | Filter: you. Refrigerant: technician |
| Pan full, AC shut off | Float switch doing its job; drain blocked | Clear the drain; technician if unsure |
| Water dripping from a pump | Failed condensate pump | Technician |
| Ceiling stain under attic unit | Overflowing or rusted secondary pan | Technician |
| Water dripping outside by the house | Normal drain outlet | Nothing to fix |
Clearing a clogged drain line
Many systems have a T-shaped cleanout with a cap on the drain line near the indoor unit. With the system off, you can remove the cap and flush the line with a cup of warm water to see whether it drains.
A wet-dry vacuum on the outdoor end of the drain can pull a clog out. Some manufacturers and contractors suggest a small amount of distilled vinegar in the cleanout to discourage algae; check your equipment manual first, and never mix cleaning chemicals.
If water does not flow, the clog is deeper, or the line was installed without enough slope, call a technician. ENERGY STAR’s maintenance checklist lists checking the condensate drain as contractor work, because a plugged drain can cause water damage and affect indoor humidity.
When to stop and call
Do not open the outdoor unit, furnace cabinet or control box. Capacitors can hold a dangerous charge with the power off, and line-voltage work is for a licensed technician.
Adding refrigerant, finding leaks or even attaching gauges requires EPA Section 608 certification.
Keep the system off and call.
Recurring ice points to low refrigerant or an airflow fault. See AC unit freezing up.
A pan replacement means working inside the unit.
What a technician will do
They will clear and flush the drain, check its slope and trap, test the float switch and any condensate pump, inspect the primary and secondary pans, and check why the coil froze if it did. On attic units, a secondary pan with its own float switch is a common safeguard.
HyreHVAC publishes no repair prices yet; use the repair cost calculator with your own quote.
Get connected
Tell us about the work
Three short steps: the job, your home, and how to reach you. Nothing goes to an HVAC company unless you agree.
A person reads it and replies, free and with no obligation. Matching is not live yet, so this is not a quote. If you smell gas or a CO alarm sounds, leave the house and call 911 or your gas utility first.
Get HVAC Options
A person at HyreHVAC reads the request and replies. Matching with contractors is not live yet, so this is not a quote.
Questions
Why is my AC leaking water inside?
Is it safe to run my AC if it is leaking water?
How do I unclog my AC drain line?
Can low refrigerant cause water leaks?
Why does my AC drip outside?
Written and audited by
HYRE HVAC Research Desk
Primary-source research, data analysis and fact checking
We are a research desk, not a sales floor. We read the federal microdata file, the statute or the manufacturer data sheet ourselves, and we publish the figure with the document it came from and the date we retrieved it.
Where a number cannot be traced to a primary source, we publish the shorter page and say what we could not verify.
The counts below are generated from the published pages themselves, last counted October 26, 2026, and they are what we have actually published rather than what we intend to.
- 18
- studies published
- 15
- federal sources read and cited
- 15
- studies published with their full dataset as CSV
- 51
- jurisdictions reproduced against EIA’s own tables
How this desk works
- Primary sources only. Federal data comes from the agency that collects it, in the file that agency publishes. We do not cite an article that cites a source; we download the source and compute the figure ourselves.
- We validate against the agency before we publish. First, we use each federal microdata file to reproduce the agency’s own published tables. Our cooling research reproduces EIA’s state estimates and standard errors for all 51 jurisdictions. That check caught a variance formula that was off by a factor of four.
- Every estimate carries its uncertainty. These are survey figures, not counts. Standard errors are computed from the replicate weights the federal file supplies and printed beside the estimate. An estimate too imprecise to publish is reported as such rather than printed.
- Nothing is typed by hand. Prose, tables and charts all read from one dataset built by script, so a number in a sentence and the same number in the table below it cannot disagree.
- We publish the data, not just the conclusion. 15 of our 18 studies offer the full computed table as a CSV download on the page, so you can check the analysis or disagree with it. A study without a row-level dataset gets no download link and claims none in its structured data.
- We correct in public. Where we have published a figure wrongly we fix the figure, rewrite any analysis that rested on it rather than patching the number underneath it, and leave a dated correction note on the page.
- We do not install or sell HVAC equipment, and we take no payment for placement, ranking or a favorable mention. Nobody buys a position on this site.
Data as of Sources checked October 26, 2026. Authorship on this site is organizational: the analysis belongs to the desk rather than to a named individual, and we do not publish credentials we do not hold. Our editorial policy sets out how we source, date and correct what we publish.
Sources & retrieval dates
HyreHVAC is a publisher. We do not install, repair or inspect HVAC equipment and hold no contractor licence. Nothing here replaces an on-site diagnosis by a licensed contractor. Sources are cited with the date they were checked.