Best temperature to set your thermostat in winter

A comfortable setting while you are home, and a lower one while you sleep or are out.

Updated October 2026 · Data as of Sources checked October 26, 2026

Written by HYRE HVAC Research Desk Primary-source research, data analysis and fact checking

The short version

The best temperature to set your thermostat in winter is the lowest you are comfortable with while home and awake, often around 68°F, then lower while you sleep or are out.

DOE’s guideline is that turning the thermostat back 7 to 10°F for eight hours a day can save as much as 10% a year on heating and cooling. Heat pumps need a gentler approach.

Why does a lower setting save energy?

Your house loses heat to the outdoors all the time. The bigger the gap between inside and outside, the faster it loses heat. Lowering the setting shrinks that gap, so the heating system runs less.

DOE’s Building America Solution Center states the guideline: as much as 10% a year by setting back 7 to 10°F for eight hours a day from the normal setting. It also notes that savings are larger in mild climates than in severe ones. Treat 10% as an upper figure, not a promise.

A simple winter schedule

TimeSetting ideaWhy
Home and awakeThe lowest you are comfortable with, often near 68°FComfort is the baseline
AsleepSeveral degrees lowerBlankets carry you; eight hours is the DOE setback window
Out at workSeveral degrees lowerNo one to keep warm
Away for daysLow, but well above freezingProtects pipes; set it, do not turn heat off

Pick numbers your household can live with. The savings come from the hours at the lower setting.

Does setback work with a heat pump?

Yes, but carefully. When a heat pump has to raise the house several degrees fast, it may call on electric resistance backup heat, which costs more to run. That can cancel out the savings.

DOE’s guidance is to use a programmable thermostat with adaptive recovery in heat pump homes. Adaptive recovery starts warming early and slowly, so the heat pump does the work instead of the heat strips. Smaller setbacks of a few degrees are often the better choice with a heat pump.

Who should not set the heat low?

Infants, older adults and people with some health conditions

Keep the home warm enough for the most vulnerable person in it.

Homes with pipes on outside walls

A deep setback in a hard freeze can risk frozen pipes.

If a CO alarm sounds

Leave the house, then call 911 or your gas utility from outside. CPSC advises CO alarms on every level and outside sleeping areas.

Ways to stay warm at a lower setting

Use a programmable or smart thermostat

It makes the setback happen without anyone remembering.

Seal drafts at doors and windows

Less cold air means the same setting feels warmer.

Keep supply vents and returns clear

Furniture over a vent blocks airflow.

Change the filter on time

A clogged filter cuts heat output. See filter intervals.

How much would you save?

It depends on your fuel, your climate and how deep and long the setback is. The thermostat savings calculator runs DOE’s figure as a range on your own numbers. If your system struggles to hold any setting, read thermostat not working.

Questions

Is 68 degrees warm enough in winter?
For most people who are awake and dressed for the season, yes. Adjust up for anyone vulnerable to cold.
Is it cheaper to leave the heat at one temperature all day?
Generally no. A house loses less heat when it is cooler, so a setback saves energy. Heat pumps are the exception to handle carefully.
What temperature should I set when I go on vacation in winter?
Low, but well above freezing so pipes stay safe. Do not turn the heat off.
Should I set the heat pump lower at night?
A small setback is fine. Use a thermostat with adaptive recovery so the backup strips do not do the warm-up.
Do smart thermostats really save energy?
ENERGY STAR certifies connected thermostats on measured savings. Results depend on how you use it.

Written and audited by

HYRE HVAC Research Desk

Primary-source research, data analysis and fact checking

We are a research desk, not a sales floor. We read the federal microdata file, the statute or the manufacturer data sheet ourselves, and we publish the figure with the document it came from and the date we retrieved it.

Where a number cannot be traced to a primary source, we publish the shorter page and say what we could not verify.

The counts below are generated from the published pages themselves, last counted October 26, 2026, and they are what we have actually published rather than what we intend to.

18
studies published
15
federal sources read and cited
15
studies published with their full dataset as CSV
51
jurisdictions reproduced against EIA’s own tables

How this desk works

  • Primary sources only. Federal data comes from the agency that collects it, in the file that agency publishes. We do not cite an article that cites a source; we download the source and compute the figure ourselves.
  • We validate against the agency before we publish. First, we use each federal microdata file to reproduce the agency’s own published tables. Our cooling research reproduces EIA’s state estimates and standard errors for all 51 jurisdictions. That check caught a variance formula that was off by a factor of four.
  • Every estimate carries its uncertainty. These are survey figures, not counts. Standard errors are computed from the replicate weights the federal file supplies and printed beside the estimate. An estimate too imprecise to publish is reported as such rather than printed.
  • Nothing is typed by hand. Prose, tables and charts all read from one dataset built by script, so a number in a sentence and the same number in the table below it cannot disagree.
  • We publish the data, not just the conclusion. 15 of our 18 studies offer the full computed table as a CSV download on the page, so you can check the analysis or disagree with it. A study without a row-level dataset gets no download link and claims none in its structured data.
  • We correct in public. Where we have published a figure wrongly we fix the figure, rewrite any analysis that rested on it rather than patching the number underneath it, and leave a dated correction note on the page.
  • We do not install or sell HVAC equipment, and we take no payment for placement, ranking or a favorable mention. Nobody buys a position on this site.

Data as of Sources checked October 26, 2026. Authorship on this site is organizational: the analysis belongs to the desk rather than to a named individual, and we do not publish credentials we do not hold. Our editorial policy sets out how we source, date and correct what we publish.

Sources & retrieval dates

US DOE Building America Solution Center (PNNL): Thermostat Controls , DOE setback guideline (up to 10% a year for a 7-10°F setback for 8 hours) and the adaptive-recovery advice for heat pumps. Retrieved October 26, 2026.
US CPSC: Carbon Monoxide Information Center , CO alarms on every level and outside sleeping areas; if you suspect CO poisoning, get to fresh air and call 911. Retrieved October 26, 2026.
US DOE Energy Saver: Air-Source Heat Pumps (archived copy, 2025) , How a heat pump transfers heat, the reversing valve, defrost, and auxiliary electric resistance heat. The live energy.gov page returned 404 on the check date. Retrieved October 26, 2026.

Heating not holding temperature?

Tell us the system you have, what it is doing and your zip code. Contractor matching is still being built, so this is an inquiry, not a booking or a service call.

Get HVAC Options Furnace repair guide

HyreHVAC is a publisher. We do not install, repair or inspect HVAC equipment and hold no contractor licence. Nothing here replaces an on-site diagnosis by a licensed contractor. Sources are cited with the date they were checked.